Yield Team offers the following instruments
SYSTEA EasyChem 200
Fully automated analyzer based on Direct Reading Discrete Analysis technology, sample capacity from 60 up to 75 positions dedicated to samples.


ICP 5000
Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES), is a well- established analytical technique that used to detect the presence of trace metals in an analyte. The analyte sample is introduced into the ICP as an aerosol that is carried into the center of the plasma – ionized argon gas.
FPI: CEMS-2000
The CEMS-2000 series Continuous Emission Monitoring System is a high-end environmental protection monitoring equipment developed and produced independently by Focused Photonics Inc.


FPI: OMA-2000
Full spectrum measurement and DOAS (Differential Optical Absorption Spectroscopy) algorithm, excelling in accuracy, repeatability and anti-interference with moisture and dust.
FPI: LGA-4100
In-situ, no gas sampling. No cross interference. Fast response less than one second. Diverse optical length (0.5-20m). Reliable in all harsh conditions: high temperature and pressure, dust density, moisture and corrosion


FPI: LGA-4500
Fast response. High accuracy, ppm level resolution. No cross interference. Online calibration, no zero drift. Reliable in all harsh conditions: high temperature & pressure, dust density, moisture and corrosion. International ATEX certified.
FPI: LDM-100(D)
On-line continuous monitoring for various emission sources. Combined techniques: adaptive stabilization, dynamic adaptive phase-locked amplification. Very low zero drift, patented technology of on-line calibration. Compact, easy to install, anti-lightning, high adaptability, low cost and less maintenance.


FPI: TPF-100
Full capabilities of data acquisition, processing, storage and transfer. Daily, monthly, yearly reports automatically created. Data value & curve real-time display, history data traceable.
FPI: GC-3000
Separation efficiency and signal-noise ratio enhanced by utilizing adsorption, thermal desorption technology. Complementary detection combined FID with PID in serial for an optimal sensitivity. Response time: Enable synchronous sampling and separation based on 2D chromatography, time saving.


FPI: XRF-2000
Simultaneously analyzing 28 most regular heavy metal elements, others scalable. High sensitivity, lower detection limit down to ng/m3. Truly continuous and non-destructive measurement, no pretreatment needed. No chemical, no liquid waste, reliable and less maintenance. 13 patents borne by the single analyzer. Radiation safety certified.
FPI: CEMS-2000B VOC
Measurement Range. Hundreds of VOCs including total hydrocarbon, non-methane hydrocarbon, BTEX and ordour. Automatic Operation The FID flame will light automatically after warm-up time. It is continuous online analysis, automatic cycle operation at startup. Full Heated Design